Wakebath · B2B project decision guide
Give every tray measurement a reference face and an installation stage.
Prepare a quotation pack that purchasing, the tray supplier and the enclosure installer can interpret the same way. A nominal size cannot describe the entire installation.
Short answer: Send a dimensioned plan and section with the measurement stage, reference faces, units, tray orientation, drain coordinates, floor levels and enclosure interface identified. Keep the tray installation opening separate from the finished-wall dimensions used for the enclosure. Mark measured, proposed and concealed information separately, and ask the supplier to confirm the exact model drawing before ordering.
Start with the Measurement Stage, Not a Nominal Size
A “1200 × 900 shower” can describe a catalogue size, a framing opening, a finished enclosure or an existing tray. Those are different records. Begin your enquiry with the site or room ID, survey date, units, intended tray type and construction stage. State whether the job is a replacement, renovation or new installation.
Distinguish a finished shower tray/receptor from a tile-ready former that still needs its wearing surface. The latter has additional tile, adhesive and waterproofing interfaces. Do not compare their bare dimensions or heights as if they describe the same finished assembly.
The key question is which faces define the available space at the stage when this model is installed? Some trays sit against substrate or framing before the wall finish overlaps their perimeter; others use a different junction. Obtain the model's installation section before treating a finished tiled opening as the required tray installation opening.
For example, KOHLER's K-9948/K-9949 receptor guide distinguishes a stud pocket, model-specific rough plumbing and finished-wall thickness. Its details belong to those receptors. The useful purchasing principle is to identify the installation reference faces for the offered model, rather than copy another product's dimensions or tolerances.
| Measurement record | What it describes | What to label |
|---|---|---|
| Tray installation opening | Space available for the tray at its actual installation stage | Framing, substrate, lining or other reference faces; any concealed perimeter |
| Actual tray geometry | The selected product's external envelope, outlet, upstands and landing surfaces | Exact model, drawing revision, orientation and dimension definitions |
| Finished enclosure opening | Dimensions between completed wall faces at the enclosure's measurement locations | Wall-finish status, measurement heights, wall variation and selected enclosure |
| Installed threshold | Entry level relative to the adjacent finished floor | Both elevations, their common datum and the completed support/drainage arrangement |
Draw One Plan with Clear Reference Faces and Orientation
Label the rear, left, right and entry side on a plan. Define the viewpoint—for example, looking into the shower from the entry. For a handed, quadrant or offset design, attach the supplier's plan and mark the intended version. “Left-hand drain” without a viewpoint can describe two different products.
Choose identifiable reference faces and an origin. For a rectangular layout, one practical convention is the intersection of the nominated left and rear reference faces, with X across the tray and Y towards the entry. If site walls do not form a reliable right angle, use the surveyor's agreed datum lines and show the wall deviations; do not quietly square up the sketch.
Keep units on the drawing. Record the original measured values rather than rounding them into the nearest standard size. Mark each value as measured, proposed or not yet visible, and identify its source photograph or survey sheet. This lets the supplier distinguish a firm constraint from an estimate.
Measure Wall Variation Where It Can Affect Fit
At tray level, record the opening at relevant front and rear positions and identify obstructions. Measure diagonals between clearly identified points where practical. A diagonal comparison can flag a geometry problem, but equal diagonals alone do not prove that every wall is straight, parallel and square. Record the wall condition directly as well.
For the enclosure, use its required measurement locations after the wall finishes are complete, or clearly label a pre-finish prediction. Note width at the relevant heights, wall plumb, returns, nibs, skirting, pipe boxes and ceiling restrictions. The enclosure's documented adjustment range must accommodate the actual geometry; it is not a general allowance for an incorrectly fitted tray.
Use suitable measuring tools, check the important readings and note any obstruction that prevents a reliable measurement. Ask the responsible installer or surveyor to confirm critical concealed or inaccessible dimensions. A scale placed in a photograph helps identify a feature but does not remove perspective error or verify a hidden edge.
Locate the Drain from Named Datums
Record the outlet centre with two coordinates from the stated reference faces or datum lines. Mark the centre, not the near edge of the opening. For a slot or off-centre outlet, use the product drawing to identify the intended dimension points and orientation.
Distinguish the tray outlet centre, the pipe centre and the floor cut-out. They may have different positions, sizes and allowable connection arrangements. Include the selected waste/trap drawing, connection direction and the space needed to assemble, test and service it. A matching outlet diameter does not confirm the whole connection will fit.
If an existing pipe cannot move, show its measured location and elevation as fixed. Ask whether the actual tray-and-waste combination can connect within the available envelope. Do not assume a flexible connector, an offset adapter or moving the tray will solve the conflict without checking the permitted installation and support details.
| Drainage field | Useful record | Mistake to avoid |
|---|---|---|
| Outlet position | X and Y to the centre, named datums, units and tray orientation | “200 from wall” without identifying wall face or centre/edge |
| Outlet interface | Exact tray outlet geometry and specified compatible waste | Treating nominal diameter as a complete compatibility check |
| Existing connection | Pipe position, elevation, direction and whether it can move | Copying a photograph without a level or coordinate reference |
| Floor opening | Actual opening dimensions and position, with structural constraints | Assuming the outlet hole and structural cut-out are the same |
| Service envelope | Waste/trap, pipe route, assembly space and access strategy | Checking only the decorative cover or top of the tray |
Use a Section to Check the Finished Entry Level
Choose a common level datum and show the structural floor, tray support interface, tray entry edge and adjacent finished floor. Add the proposed bedding or support system, recess, waste/trap envelope and pipe route. Mark which construction levels are already fixed.
The finished entry step is the difference between the entry-edge elevation and the adjacent finished-floor elevation. A product's overall height, edge height and material wall thickness describe different things; none alone determines that step. Ask which height the catalogue figure represents.
Do not simply add a trap's maximum depth to the product height. Parts of the trap, tray underside and support space may overlap, while the pipe route or connection can impose another constraint. Check the combined section against the actual assembly. The plumbing designer or installer should establish the drainage layout and required fall under the applicable rules; a generic pipe slope copied from another market does not settle the design.
For an accessible project, give the reviewer the completed entry and room arrangement. The US Access Board's bathing-room guide distinguishes shower types, clearances, thresholds and enclosure obstructions. A tray marketed as low-profile does not by itself establish that the installed shower meets the relevant accessibility requirements.
Coordinate Support, Waterproofing and the Enclosure Landing
Show the floor construction and proposed support arrangement. Confirm how loads reach the supporting floor, where the waste opening interrupts that support, and whether framing, joists or services constrain the design. Do not cut a structural member or enlarge a structural opening merely to make the trap fit; obtain the responsible building/structural review first.
Ask for the selected tray's current installation and waterproofing-junction detail. Record upstands, sealing interfaces, wall-finish overlaps and any enclosure fixing zones. A bed, frame or set of feet approved for one construction should not be assumed suitable for a different product. Likewise, a straightedge across a designed sloping bathing surface cannot establish that the tray perimeter is incorrectly level.
Mark where the glass or enclosure profile is intended to land. Check usable landing width, wall returns, any permitted drilling zone, door sweep and nearby fixtures against the actual enclosure. Keep a product's external edge, the enclosure's nominal size and its installed glass line distinguishable on the plan.
| Interface | Information to exchange before release |
|---|---|
| Tray and supporting floor | Model-specific support instructions, floor condition, opening and load-path review |
| Tray and wall finish | Junction section showing actual reference faces, overlaps, upstands and sealing system |
| Tray and waste | Compatible assembly, dimensions, connection method, test and service access |
| Tray and enclosure | Selected models, landing line, adjustment range, fixing constraints and door clearance |
| Entry and adjacent room | Common-datum elevations, finished build-ups, access requirements and water-control design |
Treat Standards and Product Drawings as Different Evidence
Use the project's destination and application to identify required product and installation evidence. Product testing, room compliance and dimensional compatibility are separate checks. Record the exact model, standard/edition where applicable, document scope and responsible reviewer.
| Evidence source | What it helps establish | What the enquiry still needs |
|---|---|---|
| BSI's BS EN 14527:2016+A1:2018 scope | A shower-tray cleanability/durability evaluation framework for its stated intended use | Model-linked evidence plus the actual dimensioned drawing and installation detail |
| US Access Board bathing-room guidance | Accessibility requirements for the relevant shower/room arrangement | Project scoping and completed clearances, entry, controls and enclosure layout |
| New Zealand MBIE E3/AS1 resources | A compliance pathway addressing internal-moisture junctions and penetrations | The project's selected compliance route and detailed tray/wall/floor junction |
| Exact-model manufacturer instructions | Product-specific installation references, support and connection requirements | Confirmation that the supplied revision/configuration matches the project |
The BSI public scope covers cleanability and durability with installation, use and maintenance according to the manufacturer's instructions. It includes hotels within domestic purposes. That does not turn a nominal catalogue size into a fit guarantee or establish a universal site clearance.
For New Zealand projects, MBIE's E3/AS1 resource page describes an acceptable-solution route for internal moisture, including junctions and penetrations. Have the project reviewer identify the applicable detail. Do not transfer one jurisdiction's waterproofing arrangement to every destination.
Worked Example: Two Correct Measurements Used Different Wall Faces
Consider a hypothetical renovation. The tray installation opening is measured as 1200 mm between the reference substrate faces. A proposed wall finish projects 12 mm into the space on each side. If that build-up is confirmed, the corresponding finished span is 1176 mm. These values describe different stages; neither should overwrite the other in the brief.
The drain centre is 200 mm from the left substrate face. Relative to the proposed finished face on that side, the coordinate would be 188 mm. Writing only “drain 200 from left wall” allows the supplier and installer to interpret the location differently.
The buyer sends both dimension sets with their face labels and the installation section. The tray supplier checks the actual product and junction against the installation opening; the enclosure supplier checks the finished opening against the selected enclosure's range. After the wall finish is completed, the installer remeasures before the enclosure is released.
The arithmetic illustrates a datum change, not a prescribed wall thickness or permission to order a 1200 mm tray. Actual product dimensions, junctions and agreed installation allowances still control fit. If a finish or model changes, update the affected coordinates and obtain the relevant review before proceeding.
Hand Over a Measurement Pack with Named Decisions
Send one controlled pack containing the plan, section, photographs and measurement register. Give it a room/site ID and revision. Identify fixed constraints, predicted finishes and unresolved measurements. Keep procurement's quotation assumptions visible to the people doing the installation.
| Owner | Decision to close | Handoff record |
|---|---|---|
| Site surveyor / installer | Actual geometry, reference faces, levels and access | Dated measurement sheet, marked plan/section and photograph references |
| Designer / building team | Wall/floor build-ups, structure and waterproofing interfaces | Reviewed junctions, levels and any approved changes |
| Tray supplier | Exact product envelope, outlet, support and permitted modifications | Model/revision drawing and installation information |
| Enclosure supplier / installer | Finished opening, landing line, adjustment and usable entry | Model-specific dimension check and installation constraints |
| Buyer | Comparable quotation scope and open assumptions | Configuration, quantities, included waste/accessories and decision register |
For an initial budget enquiry, mark missing items and request a conditional scope. Before an order or installation release, name which critical measurements and interfaces remain unresolved and who must close them. “Size confirmed” should identify the record and stage that were actually checked.
Questions Buyers Ask Before Requesting a Tray Quote
Should I measure before or after tiling?
Record both stages when they affect the assembly. The tray's installation references come from its model-specific detail; the enclosure needs the finished-wall dimensions at its specified measurement points. Label a proposed finish calculation as a prediction and remeasure when the actual finish is complete.
How much clearance should I leave around the tray?
Use the selected model's installation detail and the agreed junction design. There is no single allowance in this article that applies to every material, upstand, wall construction or installation method. Give the supplier the raw measurements and request the required fit conditions rather than subtracting an arbitrary amount.
Can I cut a larger tray to fit an awkward opening?
Only where the manufacturer confirms that the exact model permits it, with the cutting zone, method, finished-edge treatment, support and relevant warranty conditions defined. Do not infer cutability from “resin,” “composite” or a photograph, and do not cut to compensate for an unresolved drainage or enclosure conflict.
Send a Measurement Pack That Supports a Useful Quote
Send Wakebath the site plan and section, survey stage and reference faces, measured dimensions and levels, intended model/shape/handing, outlet coordinates, floor/support constraints and proposed enclosure. Add quantities, destination and the date by which the next decision is needed.
Mark what is measured, proposed or still concealed. Ask for an identified tray configuration, the drawing and installation information to review, included waste/accessories and a response to each open interface. This gives purchasing a scope to compare and gives the installer measurements that can be traced back to the site.
References and Further Reading
- BSI — BS EN 14527:2016+A1:2018, Shower trays for domestic purposes: public scope of product evaluation; obtain applicable model evidence and current installation information.
- US Access Board — Chapter 6, Bathing Rooms: accessibility guidance, including shower type, clearances, thresholds and enclosure interfaces.
- MBIE — Acceptable Solutions and Verification Methods for E3 Internal Moisture: New Zealand compliance resources for internal-moisture details; the project reviewer selects the applicable route.
- KOHLER — K-9948/K-9949 Shower Receptor Installation Guide, 1092413-2-A: a specific example distinguishing framing, rough plumbing and finished-wall considerations; its dimensions and tolerances are not universal.